Co-Authors
This is a "connection" page, showing publications co-authored by Ozer Algan and Salahuddin Ahmad.
Connection Strength
1.177
-
Dosimetric comparison of sector-blocked and non-sector-blocked Gamma Knife Perfexion treatment plans for trigeminal neuralgia. Med Dosim. 2018 Winter; 43(4):390-393.
Score: 0.154
-
Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Whole Brain Hippocampal Sparing Treatment Plans Based on Radiobiological Modeling. J Med Phys. 2018 Jan-Mar; 43(1):16-22.
Score: 0.153
-
Comparison of doses received by the hippocampus in patients treated with single isocenter- vs multiple isocenter-based stereotactic radiation therapy to the brain for multiple brain metastases. Med Dosim. 2015; 40(4):314-7.
Score: 0.127
-
Quantitative assessment by measurement and modeling of mobile target elongation in cone-beam computed tomographic imaging. J Appl Clin Med Phys. 2014 May 08; 15(3):4634.
Score: 0.119
-
Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy - for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma. J Med Phys. 2013 Oct; 38(4):165-72.
Score: 0.114
-
The dosimetric impact of daily setup error on target volumes and surrounding normal tissue in the treatment of prostate cancer with intensity-modulated radiation therapy. Med Dosim. 2012; 37(4):406-11.
Score: 0.103
-
Evaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on-board imaging. J Appl Clin Med Phys. 2010 May 20; 11(3):3192.
Score: 0.090
-
Quantitative evaluation of increase in surface dose by immobilization thermoplastic masks and superficial dosimetry using Gafchromic EBT film and Monte Carlo calculations. J Xray Sci Technol. 2010; 18(3):319-26.
Score: 0.088
-
A comparative study of seed localization and dose calculation on pre- and post-implantation ultrasound and CT images for low-dose-rate prostate brachytherapy. Phys Med Biol. 2009 Sep 21; 54(18):5595-611.
Score: 0.086
-
Quantitative evaluation of patient setup uncertainty of stereotactic radiotherapy with the frameless 6D ExacTrac system using statistical modeling. J Appl Clin Med Phys. 2016 05 08; 17(3):111-127.
Score: 0.034
-
Dosimetric comparison of intracranial metastasis treatment using two radiosurgery systems: TrueBeam STx with VMAT and Gamma Knife Model 4C. J Radiosurg SBRT. 2016; 4(3):235-243.
Score: 0.033
-
Dependency of planned dose perturbation (PDP) on the spatial resolution of MapCHECK 2 detectors. J Appl Clin Med Phys. 2014 Jan 06; 15(1):4457.
Score: 0.029
-
Linear accelerator based intracranial and extracranial stereotactic radiation therapy at the University of Oklahoma. J Okla State Med Assoc. 2011 Mar; 104(3):94-8.
Score: 0.024
-
The efficacy of radiotherapy in the treatment of orbital pseudotumor. Int J Radiat Oncol Biol Phys. 2011 Apr 01; 79(5):1496-502.
Score: 0.023