Header Logo

Connection

Imad Ali to Radiotherapy Planning, Computer-Assisted

This is a "connection" page, showing publications Imad Ali has written about Radiotherapy Planning, Computer-Assisted.
  1. Quantitative evaluation of dosimetric uncertainties associated with small electron fields. J Med Imaging Radiat Sci. 2022 06; 53(2):273-282.
    View in: PubMed
    Score: 0.756
  2. Quantitative evaluation of dosimetric uncertainties in electron therapy by measurement and calculation using the electron Monte Carlo dose algorithm in the Eclipse treatment planning system. J Appl Clin Med Phys. 2022 Jan; 23(1):e13478.
    View in: PubMed
    Score: 0.740
  3. Quantitative evaluation of the performance of different deformable image registration algorithms in helical, axial, and cone-beam CT images using a mobile phantom. J Appl Clin Med Phys. 2018 Mar; 19(2):62-73.
    View in: PubMed
    Score: 0.570
  4. Modeling and measurement of the variations of CT number distributions for mobile targets in cone-beam computed tomographic imaging. J Appl Clin Med Phys. 2015 Jan 08; 16(1):5067.
    View in: PubMed
    Score: 0.460
  5. Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance. Med Dosim. 2013; 38(3):255-61.
    View in: PubMed
    Score: 0.407
  6. Evaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on-board imaging. J Appl Clin Med Phys. 2010 May 20; 11(3):3192.
    View in: PubMed
    Score: 0.333
  7. Quantitative evaluation of patient setup uncertainty of stereotactic radiotherapy with the frameless 6D ExacTrac system using statistical modeling. J Appl Clin Med Phys. 2016 05 08; 17(3):111-127.
    View in: PubMed
    Score: 0.126
  8. Dosimetric effects of positioning shifts using 6D-frameless stereotactic Brainlab system in hypofractionated intracranial radiotherapy. J Appl Clin Med Phys. 2016 01 08; 17(1):102-111.
    View in: PubMed
    Score: 0.123
  9. The dosimetric impact of daily setup error on target volumes and surrounding normal tissue in the treatment of prostate cancer with intensity-modulated radiation therapy. Med Dosim. 2012; 37(4):406-11.
    View in: PubMed
    Score: 0.095
  10. An algorithm to extract three-dimensional motion by marker tracking in the kV projections from an on-board imager: four-dimensional cone-beam CT and tumor tracking implications. J Appl Clin Med Phys. 2011 Feb 01; 12(2):3407.
    View in: PubMed
    Score: 0.087
  11. Prospects for quantitative two-dimensional radiochromic film dosimetry for low dose-rate brachytherapy sources. Med Phys. 2006 Dec; 33(12):4622-34.
    View in: PubMed
    Score: 0.016
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.