Warren Jackman to Catheter Ablation
This is a "connection" page, showing publications Warren Jackman has written about Catheter Ablation.
Connection Strength
11.250
-
Accessory pathway recording and ablation. Heart Rhythm. 2021 05; 18(5):833-834.
Score: 0.637
-
Can We Produce Deeper Radiofrequency Lesions? JACC Clin Electrophysiol. 2017 10; 3(10):1111-1113.
Score: 0.492
-
Recording the Accessory His Bundle Potential from a Right Atriofascicular Accessory Pathway. Card Electrophysiol Clin. 2016 12; 8(4):765-766.
Score: 0.469
-
Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size. Circ Arrhythm Electrophysiol. 2014 Dec; 7(6):1174-80.
Score: 0.407
-
Electroporation (revival of direct current ablation): new approach for increasing epicardial ablation safety in close proximity to a coronary artery. Circ Arrhythm Electrophysiol. 2014 Oct; 7(5):779-80.
Score: 0.404
-
Unravelling the paradoxical effects of ganglia ablation. Circ Arrhythm Electrophysiol. 2014 Aug; 7(4):570-2.
Score: 0.399
-
Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation. Circ Arrhythm Electrophysiol. 2013 Aug; 6(4):746-53.
Score: 0.372
-
Safety of the open-irrigated ablation catheter for radiofrequency ablation: safety analysis from six clinical studies. Pacing Clin Electrophysiol. 2012 Sep; 35(9):1081-9.
Score: 0.347
-
Pathophysiologic basis of autonomic ganglionated plexus ablation in patients with atrial fibrillation. Heart Rhythm. 2009 Dec; 6(12 Suppl):S26-34.
Score: 0.287
-
Linear left atrial lesions in minimally invasive surgical ablation of persistent atrial fibrillation: techniques for assessing conduction block across surgical lesions. Heart Rhythm. 2009 Dec; 6(12 Suppl):S50-63.
Score: 0.285
-
Localization of left atrial ganglionated plexi in patients with atrial fibrillation. J Cardiovasc Electrophysiol. 2009 Oct; 20(10):1186-9.
Score: 0.280
-
Canine model of esophageal injury and atrial-esophageal fistula after applications of forward-firing high-intensity focused ultrasound and side-firing unfocused ultrasound in the left atrium and inside the pulmonary vein. Circ Arrhythm Electrophysiol. 2009 Feb; 2(1):41-9.
Score: 0.270
-
Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol. 2008 Dec; 1(5):354-62.
Score: 0.270
-
Limitations of esophageal temperature-monitoring to prevent esophageal injury during atrial fibrillation ablation. Circ Arrhythm Electrophysiol. 2008 Aug; 1(3):150-2.
Score: 0.263
-
Catheter ablation of paroxysmal supraventricular tachycardia. Circulation. 2007 Nov 20; 116(21):2465-78.
Score: 0.251
-
Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop. Circulation. 2006 Jan 03; 113(1):11-9.
Score: 0.220
-
Comparison of cryothermia and radiofrequency current in safety and efficacy of catheter ablation within the canine coronary sinus close to the left circumflex coronary artery. J Cardiovasc Electrophysiol. 2005 Nov; 16(11):1218-26.
Score: 0.218
-
Experimental model of inappropriate sinus tachycardia: initiation and ablation. J Interv Card Electrophysiol. 2005 Jun; 13(1):21-9.
Score: 0.211
-
Saline-irrigated radiofrequency ablation electrode with external cooling. J Cardiovasc Electrophysiol. 2005 Mar; 16(3):323-8.
Score: 0.208
-
High incidence of thrombus formation without impedance rise during radiofrequency ablation using electrode temperature control. Pacing Clin Electrophysiol. 2003 May; 26(5):1227-37.
Score: 0.183
-
Catheter ablation of macroreentrant atrial tachycardia in patients following atriotomy. Eur Heart J. 2002 Oct; 23(20):1566-8.
Score: 0.176
-
Transseptal left heart catheterization for cardiac ablation procedures. J Interv Card Electrophysiol. 2001 Mar; 5(1):89-95.
Score: 0.157
-
Catheter ablation of cardiac autonomic nerves for prevention of vagal atrial fibrillation. Circulation. 2000 Nov 28; 102(22):2774-80.
Score: 0.155
-
A Lattice-Tip Temperature-Controlled Radiofrequency Ablation Catheter for Wide Thermal Lesions: First-in-Human Experience With Atrial Fibrillation. JACC Clin Electrophysiol. 2020 05; 6(5):507-519.
Score: 0.147
-
A Lattice-Tip Temperature-Controlled Radiofrequency Ablation Catheter: Durability of Pulmonary Vein Isolation and Linear Lesion Block. JACC Clin Electrophysiol. 2020 06; 6(6):623-635.
Score: 0.146
-
Use of a 3-dimensional electroanatomical mapping system for catheter ablation of macroreentrant right atrial tachycardia following atriotomy. J Electrocardiol. 1999; 32 Suppl:16-21.
Score: 0.136
-
Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling. Circulation. 1998 Aug 04; 98(5):458-65.
Score: 0.132
-
Use of a three-dimensional, nonfluoroscopic mapping system for catheter ablation of typical atrial flutter. Pacing Clin Electrophysiol. 1998 Jun; 21(6):1279-86.
Score: 0.130
-
Wide QRS Complex After Catheter Ablation. Circulation. 2018 04 10; 137(15):1634-1637.
Score: 0.129
-
Development and validation of an ECG algorithm for identifying accessory pathway ablation site in Wolff-Parkinson-White syndrome. J Cardiovasc Electrophysiol. 1998 Jan; 9(1):2-12.
Score: 0.126
-
Why a large tip electrode makes a deeper radiofrequency lesion: effects of increase in electrode cooling and electrode-tissue interface area. J Cardiovasc Electrophysiol. 1998 Jan; 9(1):47-54.
Score: 0.126
-
2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace. 2018 01 01; 20(1):e1-e160.
Score: 0.126
-
2017?HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary. Europace. 2018 01 01; 20(1):157-208.
Score: 0.126
-
2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary. J Interv Card Electrophysiol. 2017 Oct; 50(1):1-55.
Score: 0.124
-
Role of the tricuspid annulus and the eustachian valve/ridge on atrial flutter. Relevance to catheter ablation of the septal isthmus and a new technique for rapid identification of ablation success. Circulation. 1996 Aug 01; 94(3):407-24.
Score: 0.115
-
Thermal latency in radiofrequency ablation. Circulation. 1996 Mar 15; 93(6):1083-6.
Score: 0.112
-
Atrial inputs as determinants of atrioventricular nodal conduction: re-evaluation and new concepts. Cardiologia. 1995 Oct; 40(10):753-61.
Score: 0.108
-
Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation. 1995 Apr 15; 91(8):2264-73.
Score: 0.105
-
Radiofrequency catheter ablation of right atriofascicular (Mahaim) accessory pathways guided by accessory pathway activation potentials. Circulation. 1994 Jun; 89(6):2655-66.
Score: 0.099
-
Late potentials are unaffected by radiofrequency catheter ablation in patients with ventricular tachycardia. Pacing Clin Electrophysiol. 1994 Feb; 17(2):157-65.
Score: 0.096
-
Risk of coronary artery injury with radiofrequency ablation and cryoablation of epicardial posteroseptal accessory pathways within the coronary venous system. Circ Arrhythm Electrophysiol. 2014 Feb; 7(1):113-9.
Score: 0.096
-
Radiofrequency ablation of a concealed accessory pathway as treatment for incessant supraventricular tachycardia in a dog. J Am Vet Med Assoc. 1993 Oct 15; 203(8):1147-52.
Score: 0.094
-
Anterolateral papillary muscle ventricular tachycardia. Heart Rhythm. 2014 May; 11(5):907-8.
Score: 0.092
-
2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. J Interv Card Electrophysiol. 2012 Mar; 33(2):171-257.
Score: 0.084
-
2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society. Heart Rhythm. 2012 04; 9(4):632-696.e21.
Score: 0.084
-
2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace. 2012 Apr; 14(4):528-606.
Score: 0.084
-
Transesophageal echocardiographic assessment of pulmonary veins and left atrium in patients undergoing atrial fibrillation ablation. Echocardiography. 2011 Aug; 28(7):775-81.
Score: 0.081
-
Thoracoscopic video-assisted pulmonary vein antrum isolation, ganglionated plexus ablation, and periprocedural confirmation of ablation lesions: first results of a hybrid surgical-electrophysiological approach for atrial fibrillation. Circ Arrhythm Electrophysiol. 2011 Jun; 4(3):262-70.
Score: 0.079
-
Surgical and catheter ablative techniques for treating supraventricular tachycardia. Appl Cardiopulm Pathophysiol. 1991; 4(1):27-32.
Score: 0.078
-
Developing the Safety of Atrial Fibrillation Ablation Registry Initiative (SAFARI) as a collaborative pan-stakeholder critical path registry model: a Cardiac Safety Research Consortium "Incubator" Think Tank. Am Heart J. 2010 Oct; 160(4):619-26.
Score: 0.077
-
Planning the Safety of Atrial Fibrillation Ablation Registry Initiative (SAFARI) as a Collaborative Pan-Stakeholder Critical Path Registry Model: a Cardiac Safety Research Consortium "Incubator" Think Tank. Am Heart J. 2010 Jan; 159(1):17-24.
Score: 0.073
-
A new epicardial lesion set for minimal access left atrial maze: the Dallas lesion set. Ann Thorac Surg. 2009 Nov; 88(5):1655-7.
Score: 0.072
-
Totally thorascopic surgical ablation of persistent AF and long-standing persistent atrial fibrillation using the "Dallas" lesion set. Heart Rhythm. 2009 Dec; 6(12 Suppl):S64-70.
Score: 0.071
-
Autonomic mechanism for initiation of rapid firing from atria and pulmonary veins: evidence by ablation of ganglionated plexi. Cardiovasc Res. 2009 Nov 01; 84(2):245-52.
Score: 0.070
-
An acute experimental model demonstrating 2 different forms of sustained atrial tachyarrhythmias. Circ Arrhythm Electrophysiol. 2009 Aug; 2(4):384-92.
Score: 0.069
-
Irrigated radiofrequency catheter ablation guided by electroanatomic mapping for recurrent ventricular tachycardia after myocardial infarction: the multicenter thermocool ventricular tachycardia ablation trial. Circulation. 2008 Dec 16; 118(25):2773-82.
Score: 0.067
-
HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society. Europace. 2007 Jun; 9(6):335-79.
Score: 0.061
-
HRS/EHRA/ECAS expert Consensus Statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2007 Jun; 4(6):816-61.
Score: 0.060
-
A novel mesh electrode catheter for mapping and radiofrequency delivery at the left atrium-pulmonary vein junction: a single-catheter approach to pulmonary vein antrum isolation. J Cardiovasc Electrophysiol. 2007 Feb; 18(2):206-11.
Score: 0.059
-
Catheter cryoablation of supraventricular tachycardia: results of the multicenter prospective "frosty" trial. Heart Rhythm. 2004 Jul; 1(2):129-38.
Score: 0.050
-
Relation between pulmonary vein firing and extent of left atrial-pulmonary vein connection in patients with atrial fibrillation. Circulation. 2004 Mar 30; 109(12):1523-9.
Score: 0.049
-
Pulmonary vein isolation during atrial fibrillation: insight into the mechanism of pulmonary vein firing. J Cardiovasc Electrophysiol. 2003 Mar; 14(3):261-2.
Score: 0.045
-
Ventricular mapping during atrial and ventricular pacing. Relationship of multipotential electrograms to ventricular tachycardia reentry circuits after myocardial infarction. Eur Heart J. 2002 Jul; 23(14):1131-8.
Score: 0.043
-
Radiofrequency catheter ablation with the split-tip electrode in the temperature-controlled mode. Pacing Clin Electrophysiol. 2001 Dec; 24(12):1765-73.
Score: 0.041
-
Reversing the direction of paced ventricular and atrial wavefronts reveals an oblique course in accessory AV pathways and improves localization for catheter ablation. Circulation. 2001 Jul 31; 104(5):550-6.
Score: 0.041
-
Characterization of reentrant circuit in macroreentrant right atrial tachycardia after surgical repair of congenital heart disease: isolated channels between scars allow "focal" ablation. Circulation. 2001 Feb 06; 103(5):699-709.
Score: 0.039
-
Slow/Fast Atrioventricular Nodal Reentrant Tachycardia Using the Inferolateral Left Atrial Slow Pathway: Role of the Resetting Response to Select the Ablation Target. Circ Arrhythm Electrophysiol. 2018 09; 11(9):e006631.
Score: 0.033
-
Critical atrial site for ablation of pacing-induced atrial fibrillation in the normal dog heart. J Cardiovasc Electrophysiol. 1997 Nov; 8(11):1255-65.
Score: 0.031
-
Electrophysiology of the atrio-AV nodal inputs and exits in the normal dog heart: radiofrequency ablation using an epicardial approach. J Cardiovasc Electrophysiol. 1997 Aug; 8(8):904-15.
Score: 0.031
-
2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2017 10; 14(10):e275-e444.
Score: 0.030
-
Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node. Circulation. 1996 Sep 01; 94(5):1027-35.
Score: 0.029
-
Anatomic substrate for idiopathic left ventricular tachycardia. Circulation. 1996 Feb 01; 93(3):497-501.
Score: 0.028
-
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Clinical Intracardiac Electrophysiologic and Catheter Ablation Procedures), developed in collaboration with the North American Society of Pacing and Electrophysiology. J Am Coll Cardiol. 1995 Aug; 26(2):555-73.
Score: 0.027
-
A diagnostic algorithm to optimize data collection and interpretation of Ripple Maps in atrial tachycardias. Int J Cardiol. 2015 Nov 15; 199:391-400.
Score: 0.027
-
[Treatment of AV-nodal reentry tachycardia by transcatheter radiofrequency ablation]. Orv Hetil. 1994 Aug 20; 135(34):1853-7.
Score: 0.025
-
Characterization of the distal insertion of atriofascicular accessory pathways and mechanisms of QRS patterns in atriofascicular antidromic tachycardia. Heart Rhythm. 2013 Sep; 10(9):1385-92.
Score: 0.023
-
Unexpected potential following ablation of a right atriofascicular accessory pathway. J Cardiovasc Electrophysiol. 2013 Aug; 24(8):939-41.
Score: 0.023
-
Epicardial confirmation of conduction block during thoracoscopic surgery for atrial fibrillation--a hybrid surgical-electrophysiological approach. Minim Invasive Ther Allied Technol. 2012 Jul; 21(4):293-301.
Score: 0.021
-
2011 ACCF/AHA/HRS focused update on the management of patients with atrial fibrillation (Updating the 2006 Guideline): a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Heart Rhythm. 2011 Jan; 8(1):157-76.
Score: 0.019
-
The role of ganglionated plexi in apnea-related atrial fibrillation. J Am Coll Cardiol. 2009 Nov 24; 54(22):2075-83.
Score: 0.018
-
Atrial fibrillation begets atrial fibrillation: autonomic mechanism for atrial electrical remodeling induced by short-term rapid atrial pacing. Circ Arrhythm Electrophysiol. 2008 Aug; 1(3):184-92.
Score: 0.016
-
Autonomic mechanism to explain complex fractionated atrial electrograms (CFAE). J Cardiovasc Electrophysiol. 2007 Nov; 18(11):1197-205.
Score: 0.016
-
Interactive atrial neural network: Determining the connections between ganglionated plexi. Heart Rhythm. 2007 Jan; 4(1):56-63.
Score: 0.014
-
Electrical stimulation to identify neural elements on the heart: their role in atrial fibrillation. J Interv Card Electrophysiol. 2005 Aug; 13 Suppl 1:37-42.
Score: 0.013
-
Ventricular mapping during atrial and right ventricular pacing: relation of electrogram parameters to ventricular tachycardia reentry circuits after myocardial infarction. J Interv Card Electrophysiol. 2004 Dec; 11(3):183-91.
Score: 0.013
-
Evidence for multiple atrio-AV nodal inputs in the normal dog heart. J Cardiovasc Electrophysiol. 1998 Apr; 9(4):395-408.
Score: 0.008