Warren Jackman to Electrodes
This is a "connection" page, showing publications Warren Jackman has written about Electrodes.
Connection Strength
1.202
-
Why a large tip electrode makes a deeper radiofrequency lesion: effects of increase in electrode cooling and electrode-tissue interface area. J Cardiovasc Electrophysiol. 1998 Jan; 9(1):47-54.
Score: 0.148
-
Can We Produce Deeper Radiofrequency Lesions? JACC Clin Electrophysiol. 2017 10; 3(10):1111-1113.
Score: 0.143
-
Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size. Circ Arrhythm Electrophysiol. 2014 Dec; 7(6):1174-80.
Score: 0.119
-
Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation. Circ Arrhythm Electrophysiol. 2013 Aug; 6(4):746-53.
Score: 0.108
-
Rapid high resolution electroanatomical mapping: evaluation of a new system in a canine atrial linear lesion model. Circ Arrhythm Electrophysiol. 2012 Apr; 5(2):417-24.
Score: 0.099
-
Catheter ablation of atrioventricular junction using radiofrequency current in 17 patients. Comparison of standard and large-tip catheter electrodes. Circulation. 1991 May; 83(5):1562-76.
Score: 0.093
-
Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop. Circulation. 2006 Jan 03; 113(1):11-9.
Score: 0.064
-
Saline-irrigated radiofrequency ablation electrode with external cooling. J Cardiovasc Electrophysiol. 2005 Mar; 16(3):323-8.
Score: 0.061
-
Relation between pulmonary vein firing and extent of left atrial-pulmonary vein connection in patients with atrial fibrillation. Circulation. 2004 Mar 30; 109(12):1523-9.
Score: 0.057
-
High incidence of thrombus formation without impedance rise during radiofrequency ablation using electrode temperature control. Pacing Clin Electrophysiol. 2003 May; 26(5):1227-37.
Score: 0.053
-
Endovascular stimulation of autonomic neural elements in the superior vena cava using a flexible loop catheter. Jpn Heart J. 2003 May; 44(3):417-27.
Score: 0.053
-
Transseptal left heart catheterization for cardiac ablation procedures. J Interv Card Electrophysiol. 2001 Mar; 5(1):89-95.
Score: 0.046
-
Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling. Circulation. 1998 Aug 04; 98(5):458-65.
Score: 0.038
-
Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation. 1995 Apr 15; 91(8):2264-73.
Score: 0.031
-
Epicardial confirmation of conduction block during thoracoscopic surgery for atrial fibrillation--a hybrid surgical-electrophysiological approach. Minim Invasive Ther Allied Technol. 2012 Jul; 21(4):293-301.
Score: 0.024
-
Catheter ablation of accessory atrioventricular pathways (Wolff-Parkinson-White syndrome) by radiofrequency current. N Engl J Med. 1991 Jun 06; 324(23):1605-11.
Score: 0.023
-
Use of intracardiac recordings to determine the site of drug action in paroxysmal supraventricular tachycardia. Am J Cardiol. 1988 Dec 20; 62(19):8L-19L.
Score: 0.020
-
Radiofrequency catheter ablation with the split-tip electrode in the temperature-controlled mode. Pacing Clin Electrophysiol. 2001 Dec; 24(12):1765-73.
Score: 0.012
-
Modification of a left-sided accessory atrioventricular pathway by radiofrequency current using a bipolar epicardial-endocardial electrode configuration. Eur Heart J. 1988 Aug; 9(8):927-32.
Score: 0.005
-
Percutaneous catheter ablation at the mitral annulus in canines using a bipolar epicardial-endocardial electrode configuration. Pacing Clin Electrophysiol. 1988 Jun; 11(6 Pt 1):760-75.
Score: 0.005